PPH storage tank Plays an important role in our life. It can be used for the production and processing of chemical enterprises such as pharmaceutical factories and pesticide factories, as well as the storage of raw materials in processing and manufacturing industries such as petroleum, pharmacy, food industry, vegetable oil, paper making, steel industry, ecological environment protection and industry.
1. The PPH storage tank installation site should be well ventilated, generally suitable for installation in the outdoor environment, and should be surrounded by a fence. Open fire, inflammables and explosives are strictly prohibited.
2. Grounding device and lightning protection device shall be used to conduct and avoid static electricity. The anti-static grounding resistance and impact resistance of lightning protection equipment must be properly controlled, and their resistance should be tested more frequently.
3. When using PPH tank, it is strictly prohibited to overfill.
4. The pressure gauge must be checked regularly and there is no oil. Its control valve must be made of stainless steel or copper, and must be regularly maintained and inspected to strictly drain oil
5. When valves, instruments, pipes, etc. When freezing on the equipment, nitrogen, air or hot water must be used for thawing. PPH storage tank
6. When there is liquid in PPH storage tank, thermal maintenance is prohibited, and it must be heated to normal temperature before maintenance.
7. Operators can take up their posts only after they have received vocational training and passed the examination. Do not wear clothes with oil stain, electrostatic effect and shoes with nails. During operation, the valve must be opened and closed slowly. When not in use, the booster valve must be closed firmly.
8. When the liquid in the tank has been drained and cannot be heated immediately, all valves shall be closed immediately. Due to the low temperature in the storage tank, moist air invades the interior, freezes and blocks the pipeline.
In actual installation and use, the following ten details should be noted:
1. When installing PPH winding storage tank, avoid strong impact and collision on the tank body. The connecting pipes on the oil tank must be sealed with acid resistant seals, which must be replaced as time goes by.
2. PPH spiral wound storage tank is normal temperature and pressure storage tank. The service temperature of all polyethylene plastic tank is different from that of steel plastic composite tank, which must be controlled reasonably.
3. PPH wound storage tank shall be installed and used far away from the source to avoid contact with open fire.
four PPH winding tank Good drainage ditches and dilution devices shall be set at the location.
5. When PPH wound storage tank is used to store chemicals, the stored items must be clearly marked. PPH mixing tank
6. The PPH wound storage tank must be opened during filling and outlet to avoid damaging the pressurized equipment.
7. If there is a pipe connected to the joint or flange at the bottom of the tank wrapped by PPH, the pipe should use a soft connection and should be perpendicular to the barrel wall to avoid the irregular expansion of the barrel wall after it is filled with liquid, which will damage the joint connection and lead to leakage. In serious cases, the joint and the barrel may be damaged.
8. When PPH winding storage tank is used to contain high-strength solvent, anti-static structure shall be set.
9. When the liquid inlet is higher than the tank bottom, the liquid inlet shall bend to the tank wall to make the liquid inlet fall along the tank wall to reduce the impact on the tank bottom.
10. The installation, use and maintenance of PPH storage tank shall refer to relevant standards.

The above content is collected by the Internet, and the copyright belongs to the original author. If there is any infringement, please contact us to delete the content. Thank you!