Precautions for installation of PPH storage tank

2022-01-25 17:01:56
second

PPH storage tank During in-situ transportation, hoisting and unloading, mechanical impact shall be avoided, and the connection and manual hole on the equipment shall not be taken as key points; Please use synthetic fiber sling, which can be 1/3 higher than the storage tank. It is forbidden to use steel wire rope, iron chain and hemp rope that are easy to slip; In the process of turning over and lifting the equipment, wooden strips or other cushions shall be placed to keep the equipment evenly stressed;

The foundation for tank installation shall be an integral foundation, which shall be horizontal and have sufficient bearing capacity. During installation, a cushion shall be set between the equipment contact surface and the foundation, and the cushion material can be soft plastic plate or soft rubber plate;

PPH mixing tank Before loading the equipment, check whether the exhaust port and overflow port are unblocked. It is strictly prohibited to use under overpressure (positive pressure: 3000Pa, negative pressure: - 2000Pa), and the load bearing of tank top cover during maintenance operation shall not exceed the design capacity; It is strictly prohibited to hold materials when moving and transporting storage tanks.

When the equipment is installed and used, attention should be paid to the protection of flanges and accessories. No trampling. The connection between tank flange and pipe flange shall ensure that the end faces of the two flanges are parallel and the center is not offset. Fasteners shall be correctly connected and fabricated. The force shall be uniform and the strength shall not deform the plastic flange.

The metal pipes and valves connected to the equipment must be installed with supports to avoid additional stress on the plastic nozzle. At the same time, expansion and contraction factors of plastic shall be considered, and compensators shall be used. It is strictly prohibited to connect the power pump with the flange of the water tank rigidly, and the compensator must be used.

It is forbidden to use plastic equipment over temperature, and the working medium and temperature must meet the design requirements; The scope of use shall not be changed without authorization.

It is strictly forbidden for equipment to contact with fire source. If you are engaged in electric welding and gas welding near the equipment, protective measures must be taken to prevent thermal deformation changes; The equipment shall not be installed near the vibration source, and damping measures shall be taken when it must be installed near the vibration source; Anti aging measures and methods shall be taken for outdoor equipment.


 PPH storage tank


The above content is collected and sorted by the Internet, and the copyright belongs to the original author. If there is infringement, please contact us to delete the content, thank you!


Recent browsing:

Related products

Related news

Qiheng Environmental Protection

Manager Liu: 19107778871


Address: Zone 1, Huangma Industrial Park, Qinbei District, Qinzhou, Guangxi


PPH storage tank PPH winding tank PPH mixing tank

Add friends

View mobile station